56 unique locations (631 components) - Page 1 of 3

Active MW: 35388.22 MW
Inactive MW: 1729.46 MW
Wissington Sugar Factory, British Sugar plc, College Road, Wissington, King's Lynn, PE33 9QG (16 components)

The CMU is a gas fired CCGT CHP (3)

Active • 2028-29 (T-4), 2027-28 (T-4) ...
125.98 MW
Winnington CHP, Winnington Lane, Winnington, Northwich, Cheshire, CW8 4GX (28 components)
• Continuously operating, maximum output GE gas turbine driving a 47.020MVA Alstom generator at 0.85 power factor. (2)
• Continuously operating, maximum output GE gas turbine driving a 47.020MWA Alstom generator at 0.85 power factor.
Active • 2028-29 (T-4), 2027-28 (T-4) ...
119.61 MW
Westexe, Tiverton, Devon, EX16 5LL (6 components)

2026 kW CHP unit (3)

Active • 2026-27 (T-4), 2025-26 (T-4) ...
3.65 MW
WEPA Bridgend Paper Mill, Llangynwyd, Mid Glamorgan, South Wales CF34 9RS (6 components)

Existing Generation on existing site - CHP (3)

Active • 2027-28 (T-4), 2026-27 (T-4) ...
36.30 MW
Unit 3016, Hereford Street, Bolton, BL1 8HU (6 components)

E1000 CHP (3)

Active • 2026-27 (T-4), 2025-26 (T-4) ...
1.79 MW
1.79 MW
Unit 2898, Tuscany Park, Wakefield, WF6 2TZ (6 components)

EnerG 1000 CHP (3)

Active • 2026-27 (T-4), 2025-26 (T-4) ...
1.82 MW
Treviscoe Dryer, Little Treviscoe, St. Austell, PL26 7QN (9 components)
• Gas fired CHP unit (2)
• Gas CHP in St. Austell
Combined Heat and Power (CHP) KIWI POWER LTD Existing Generating CMU KPEG55 PL26
Active • 2026-27 (T-4), 2025-26 (T-4) ...
6.12 MW
Tower Nurseries Netherhall Road Roydon Essex CM19 5JP (11 components)

Gas engines in commercial horticultural environment with no auxilliary load. All generation unit capacities are nominal and allow for site-specific variations (3)

Active • 2029-30 (T-4), 2028-29 (T-4) ...
8.20 MW
Thirsk Factory, Dalton Airfield, Topcliffe, Thirsk, YO7 3HE. (5 components)

1.280MW CHP (3)

Active • 2026-27 (T-4), 2025-26 (T-4) ...
2.34 MW
The Ridgeway , Enfield, Middlesex, EN2 8JL (12 components)
Active • 2029-30 (T-4), 2027-28 (T-4) ...
3.88 MW
Tees Valley Nursery, The Moat, Belasis Hall, TS23 4ED (21 components)

The CMU component TEES01 is one gas-fired Jenbacher CHP engine. It will be supplying heat, CO2 and power to the on-site tomato Nursery all year. (3)

Active • 2028-29 (T-4), 2027-28 (T-4) ...
18.39 MW
Stainland Boardmill, Holywell Green, Halifax, HX4 9PY (3 components)

Gas Fired CHP (3)

Combined Heat and Power (CHP) E.ON UK PLC New Build Generating CMU SON_CHP SON_CHP HX4
Active • 2027-28 (T-4), 2026-27 (T-4) ...
8.78 MW
SOUTH STAFFORDSHIRE WATER PLC, Hampton Loade Treatment Works, Hampton Loade, Bridgnorth, WV15 6HD (11 components)

Existing Generation on existing site - CHP (3)

Combined Heat and Power (CHP) GRIDBEYOND LIMITED Existing Generating CMU Rejected WV15
Active • 2029-30 (T-4), 2027-28 (T-4) ...
24.61 MW
Solvay, Trinity St, Oldbury, B69 4LW (6 components)

Existing Generation on existing site - CHP (3)

Combined Heat and Power (CHP) GRIDBEYOND LIMITED Existing Generating CMU Rejected B69
Active • 2027-28 (T-4), 2026-27 (T-4) ...
6.46 MW
Smurfit Kappa SSK, Mount Street, Nechells, Birmingham, B7 5RE (13 components)

1 x 3.5MW natural gas fired turbine + 1 x 4.8MW natural gas fired turbine (2)

Active • 2027-28 (T-4), 2026-27 (T-4) ...
7.58 MW
School Road, Aberdeen AB24 1TU (14 components)
• District heating implementation with 2 x 1.063MW CHP exporting excess to distribution network. Primary fuel type = Natural Gas. All generation unit capacities are nominal and allow for site-specific variations. Historic Average Output is 1,916.424kW.
• District heating implementation with one asset 1.943MW exporting excess to distribution network. Primary fuel type = Natural Gas
• District heating implementation with one asset 1.943MW exporting excess to distribution network. Primary fuel type = Natural Gas. All generation unit capacities are nominal and allow for site-specific variations.
Active • 2028-29 (T-4), 2027-28 (T-4) ...
6.96 MW
Royal Liverpool University Hospital, Prescott Street, Liverpool L7 8XP (12 components)
• 2 x Gas reciprocating engines with a total rated gross power capacity of 5.241 MW and total net power capacity of 5.050 MW.
• 2 x Gas reciprocating engines with a total rated gross power capacity of 5.300 MW and a net power capacity of 5.109 MW after taking into account generator auxiliary load.
• 2 x Gas reciprocating engines with a total rated gross power capacity of 5.334 MW.
CHP and autogeneration Combined Heat and Power (CHP) VEOLIA UK LIMITED Existing Generating CMU Royal Liverpool & Broadgreen Hospitals Royal Liverpool & Broadgreen Hospitals +5 more L7
Active • 2029-30 (T-4), 2026-27 (T-4) ...
14.39 MW
Rocks Dryer, Rosvear Road, Bugle, St. Austell, PL26 8PJ (9 components)
• Gas CHP
• Gas CHP in St. Austell
Combined Heat and Power (CHP) KIWI POWER LTD Existing Generating CMU KPEG54 PL26
Active • 2026-27 (T-4), 2025-26 (T-4) ...
6.71 MW
QMC Campus, Nottingham University Hospitals, Queens Medical Centre, Derby Road, Nottingham, NG7 2UH (12 components)
• A site with one gas turbine CHP, providing steam and electricity to Queen's Medical Centre at Nottingham. A new HH meter will replace the current meter with a full metering statement to follow.
• A site with one gas turbine CHP, providing steam and electricity to Queens Medical Centre in Nottingham
• A site with one gas turbine CHP, providing steam and electricity to Queens Medical Centre in Nottingham.
CHP and autogeneration Combined Heat and Power (CHP) E.ON UK PLC Existing Generating CMU OSG_AGG01 QMCCHP +5 more NG7
Active • 2027-28 (T-4), 2026-27 (T-4) ...
8.13 MW
Pond Street, London, NW3 2QG (12 components)

On-site CHP - existing generating unit Pond Street London OS Grid Reference: TQ 272 854 NW3 2QG

Active • 2029-30 (T-4), 2027-28 (T-4) ...
15.41 MW
Par CHP, Par Docks, Par, St. Austell, PL24 2BN (9 components)
• CHP unit
• Gas CHP located in St. Austell
Combined Heat and Power (CHP) KIWI POWER LTD Existing Generating CMU KPEG53 PL24
Active • 2026-27 (T-4), 2025-26 (T-4) ...
7.30 MW
Newton Aycliffe, CO Durham, DL5 6EA (30 components)

This is an existing CHP (3)

Active • 2028-29 (T-4), 2027-28 (T-4) ...
36.43 MW
Myatts Field CHP, Akerman Road, Lambeth, London, SW9 6SN (9 components)

A gas engine CHP site providing hot water to a local district heating network

Combined Heat and Power (CHP) E.ON UK PLC Existing Generating CMU CE_Aggregated CE_Aggregated +4 more SW9
Active • 2028-29 (T-4), 2027-28 (T-4) ...
0.84 MW
Moorcroft Drive, Wednesbury, WS10 7DE (6 components)

EnerG 1000 CHP

Active • 2026-27 (T-4), 2025-26 (T-4) ...
1.82 MW